| Problem | Possible Cause | Possible Solution |
|---|---|---|
| 6.5 Blank Screen and no lights | (1) Bad power cable connection/damaged cable | (1) Inspect the PLC power cable (red/black/green cable coming out of the bottom of the PLC) for damage. (2) Ensure that the PSU in the control box has power and that no breakers are flipped. |
| (2) Bad PLC | (1) Contact Spire for a replacement PLC. | |
| 6.6 Orange STOP banner at top of screen | (1) Program stopped | (1) Program has been stopped. Flip open the cover. (2) Press the green RUN button. (3) Wait up to 5 min for banner to change to green and say RUN. (4) Try operating the targets. (5) If targets do not operate, reset power on the 15" touch screen and wait for it to boot up. (6) Try to operate targets. (7) If targets do not operate, contact Spire for further troubleshooting. |