| Problem | Possible Cause | Possible Solution |
|---|---|---|
| 2.11 Misaligned target(s) | (1) Alignment error | (1) Navigate to the Menu Screen on the HMI Touch Screen. (2) Select Range Settings. (3) Enter the lane number of the target needing homing in the Target to Calibrate field. Be careful to not change the # of Targets field. (4) Press the +/- buttons until the clamp is homed correctly. (5) Press Set Reference until the Actual Angle Degree shows either 0 or 360. |
| (2) Turning motor fault. | (1) Contact Spire for technical support. | |
| 2.12 Nonresponsive target(s) (not moving) in middle of range | (1) Obstruction in drive system | (1) See 5.6. |
| (2) Turning motor fault | (1) Navigate to the Menu Screen on the HMI Touch Screen. (2) Select Range Settings. (3) Press the Reset button in the lower-left corner. (4) If problem persists, see 5.6. (5) If problem persists, contact Spire for technical support. | |
| 2.13 Nonresponsive target(s) (not moving) from the left or right end of the range through X lane | (1) Damaged ethernet cable/port | (1) See 5.1. |
| 2.14 Nonresponsive target(s) (not moving) from X lane through the last lane | (1) # of Targets set incorrectly | (1) Navigate to the Menu Screen on the HMI Touch Screen. (2) Select Range Settings. (3) Set # of Targets field to be some number higher than the # of lanes in the range. I.e. an example range has 32 lanes so you would enter 35 in the field. (4) Set # of Targets field to the number of lanes actually present in your range. I.e. in the previous example this would be 32. (5) Press the Reset button in the lower-left corner. |
| (1) Damaged ethernet cable/port | (1) See 5.1. |